Q
Impedance: 75 Ω
Q
Insulation of special PE compound, 
gas-injection foamed
Q
Metre marking
Q
Lead and silicone free
Q
Conform with EN 50117
Q
For indoor mounting
Type
 
LCD 89
LCD 90
LCD 95
Order no. 100 m
 
21510004
271648
271657
Order no. 250 m
-
21510006
21510007
Order no. 500 m
 
21510005
271650
271762
Centre conductor 
mm
0.75 Cu
1.13 Cu
1.13 Cu
Insulation
mm
3.2 PEE/PH
4.8 PEE/PH
4.8 PEE/PH
Outer conductor
mm
3.8  
1 x Triplex-Al/pet/Al film, 
1 x CuSn meshwork
5.3   
1 x Triplex-Al/pet/Al film, 
1 x CuSn meshwork
5.3   
1 x Triplex-Al/pet/Al film, 
1 x CuSn meshwork
External coating
mm
5.0 PVC white
6.8 PVC white
6.8 PVC white
Copper content
kg/km
13.0
14.0
23.0
Bending radius
mm
> 25
> 35
> 35
Reduction factor
 
0.85
0.81
0.85
Loss at 5 MHz
dB/100 m
2
1
1
Loss at 50 MHz
dB/100 m
6
4
4
Loss at 100 MHz
dB/100 m
9
6
6
Loss at 200 MHz
dB/100 m
12
8
8
Loss at 300 MHz
dB/100 m
15
10
10
Loss at 450 MHz
dB/100 m
18
13
13
Loss at 800 MHz
dB/100 m
24
18
17
Loss at 1,000 MHz
dB/100 m
28
21
19
Loss at 1,350 MHz
dB/100 m
33
25
22
Loss at 1,750 MHz
dB/100 m
38
28
26
Loss at 2,050 MHz
dB/100 m
42
31
28
Loss at 2,400 MHz
dB/100 m
45
33
31
Return loss 5-470 MHz
dB
> 20
> 20
> 26
Return loss 470-862 MHz
dB
> 18
> 18
> 23
Return loss 862-2,150 MHz
dB
> 16
> 16
> 20
DC resistance
Ω/km
< 65
< 45
< 30
Screening loss 30-1,000 MHz
dB
> 90 ¹
)
> 75
> 90
Screening loss 1,000-2,400 MHz
dB
> 90
> 65
> 90
Coupling resistance 5-30 MHz
mΩ/m
< 5 
²
)
 
-
<  5
Thermal load
MJ/m
0.68
0.73
0.68
Ambient temperature range
°C
-25 to +70
-25 to +70
-25 to +70
Packing
100 m 
One-way coil
One-way coil
One-way coil
Packing
5 x 100 m
Cardboard box
Cardboard box
Cardboard box
Packing
250 m
-
Unroll box
Unroll box
Packing
500 m
One-way drum
One-way drum
One-way drum
Weight
kg/100 m
3.0
4.8
6.1
¹
)
 30-80 MHz > 85 dB   
²
)
 5-7 MHz < 7 mΩ/m
21510004/21510005
271648/21510006/271650
271657/21510007/271762