Powercast Corporation TX91501B User Manual

Page of 7
User’s Manual 
TX91501B – 915 MHz Powercaster
 Transmitter 
 
Rev A – 2018/10 
User’s Manual - TX91501B Transmitter 
Page 2 
 
www.powercastco.com 
SET-UP AND OPERATION 
1.  Wall-mount the TX91501B in the desired location with the Powercast logo and status 
LED facing the direction in which the energy is desired.  For permanent installations, 
mount the TX91501B eight feet or more above floor level.   
2.  Plug the DC connector of the power supply into one of the two available connectors on 
the TX91501B.   Plug the power supply into a 120V outlet. 
3.  When the green LED illuminates, the TX91501B is active and transmitting radio 
frequency (RF) energy.  Data is automatically included in the transmission and can be 
received by one of Powercast’s Powerharvester Modules. 
 
The status LED indicates the following operating conditions: 
LED 
Status 
Description 
Off 
Off 
5VDC is not applied 
Green 
Active 
Transmitting normally 
Red
1 
Fault 
Transmission stopped due to an obstruction in close proximity
2 
1
During fault status, the LED will momentarily blink about once per second until the obstruction is removed. 
2
If operating on a flat surface for testing purposes, such as a table, it is recommended that the TX91501B is elevated off the surface with a non-
conducting material, such as foam or a cardboard box, OR the TX91501B is positioned near the edge for unobstructed transmission.  
 
SPECIFICATIONS 
Item 
Description 
Modulation 
Power:  Direct Sequence Spread Spectrum (DSSS) 
Data:  Amplitude Shift Keying (ASK) 
Frequency 
915 MHz Center Frequency 
Power output 
(not user adjustable) 
TX91501B-3W-XX: 
3 watts EIRP 
TX91501B-1W-XX: 
1 watt EIRP 
Beam pattern 
60° width, 60° height 
Vertical Polarization (with logo in upright position) 
Approvals 
FCC Part 15.247 
Industry Canada 
Firmware Version 
Located on the TX91501B label 
Data Communications 
An 8-bit, factory-set, TX91501B identification (ID) number is broadcast with 
random intervals up to 10ms using Amplitude Shift Keying (ASK) 
modulation.  The ID number can be found on the TX91501B label. 
Operating Temperature  -20°C to 50°C 
Installation 
Environment 
Indoor use only 
Mounting 
6 bracket mounting holes (See mechanical drawing for dimensions) 
2 keyholes (See mechanical drawing for dimensions) 
Power 
5VDC/1A through included Power Supply 
Color 
Black 
Dimensions 
6.75” x 6.25” x 1.63” (171.45 x 158.75 x 41.4 mm) 
Weight 
1 lb 
Warranty 