Essence Security International ltd. ES700ISN User Manual

Page of 1
For more information, go to: 
www.essence-grp.com
© 2013 Essence Security International (E.S.I.) Ltd. Information contained within this document may change without notice
Indoor Siren
ES700ISN
Indoor, bi-directional, battery-operated RF siren
11
Lifestyle
Product
Specifications
An indoor bi-directional RF battery-operated loud siren. It 
features:
Upon Intrusions detection, loud siren sound (105 dBA
sound output from 1 meter) is activated for 5 to 180 
seconds (user defined parameter)
Adjustable volume level
Two orange LED strobes
Two kinds of security alarm sounds, safety alarm sound, 
entry/exit beeps and chime.
Two modes: operational and maintenance 
“Plug-&-Play” state-of-the-art Wireless security system:
User-friendly
Utilizes cutting-edge technology
Bidirectional RF wireless communication
Battery operated
Easy to install
Nonintrusive, state-of-the-art design
COMMUNICATION:
Bi-directional:  End-to-End Bi-Directional ESI protocol
Advanced radio supervision algorithm
Up to 700 meters / 2296 ft. RF range (open air)
Modulation and Frequency:  BFSK , 868.3 MHz for Europe or 916.5 MHz 
for USA
Encoding:  32-bit ID, over 4 billion combinations
SECURITY:
Tamper mechanism when removed from wall mount
Unique electronic serial number
POWER  CONSUMPTION:
Long operation period (over 36 months) without external power source
Uses 4 standard AA Alkaline batteries
SIZE  and  WEIGHT: 
Dimensions: 120x120x40 mm / 4.7x4.7x1.6 In. (LxWxD) 
Weight:  150 gr. / 0.33 lb. (batteries: 100 gr. / 0.22 lb.) 
ENVIRONMENT:
Operating Ambient Temperature range: -10°C ~ 55°C / 14°F ~ 131°F 
Humidity: up to 95%, non condensing 
CERTIFICATION:
CE: CE mark, EMC/EMI according to 
ETSI EN 301 489-4, ETSI EN 301 489-1, EN 50130-4:1996,
EU Directive 1999/5/EC for R&TTE 
Radio: ETSI EN 300 220-3, ETSI EN 300 220-1, CEPT/ERC 
Recommendation 70-03,  EN 50131-5-3:2005 + A1:2008 
Safety:  EN/IEC60950-1, TUV :  UL 60950-1 
Security & Alarm systems: EN 50131-1:2006 + A1:2009 Class-II Grade-
2, EN 50131-4:2009 Class-II Grade-2, 
EN50131-6:2008 Type-C
Environmental Regulation: RoHS 2002/95/EC
Reliability (Mechanical & Environmental conditions):  
EN 50130-5:1999 and IEC 60068
Manufacturing and Materials Standards: ISO 9001:2008, 
ISO 14000
Certifications and approvals:
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can radiate 
radio frequency energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following measures: 
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by the party responsible for 
compliance (Essence Security International Ltd.) could void the user’s authority to operate the 
equipment.
WARNING! To comply with FCC RF exposure compliance requirements, the device should be located at 
a distance of at least 20 cm from all persons during normal operation. The antennas used for this 
product must not be co-located or operated in conjunction with any other antenna or transmitter.
This device complies with FCC Rules Part 15. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference,  and
(2) This device must accept any interference received, including interference that may
cause undesired operation