Moxa NPort 5610-8-48V NPORT 5610-8-48V User Manual

Product codes
NPORT 5610-8-48V
Page of 3
1
w w w. m o x a . c o m
i n f o @ m o x a . c o m
Serial-to-Ethernet Device Servers
8
NPort® 5600 Rackmount Series
Serial-to-Ethernet Device Ser
vers  >
Appearance
Overview
NPort
®
 5600 Rackmount Series
8 and 16-port RS-232/422/485 serial device servers
8 or 16 serial ports supporting RS-232/422/485
 
Standard 19-inch rackmount size
 
10/100M auto-sensing Ethernet
 
Built-in 15 KV ESD protection for all serial signals
 
Easy IP address configuration with LCD panel
 
Choice of configuration methods: Web console, Telnet console, 
 
and Windows utility
Versatile socket operation modes, including TCP Server, TCP 
 
Client, UDP, and Real COM
SNMP MIB-II for network management
 
With the NPort® 5600 rackmount series, you not only protect your 
current hardware investment, but also allow for future network 
expansion by centralizing the management of your serial devices and 
distributing management hosts over the network. 
Network Readiness for up to 16 Serial Devices
Only basic configuration is needed with the NPort® 5600 to connect 
up to 16 serial devices to an Ethernet network.
19-inch Rackmount Device Server
NPort® 5600 device servers come with Tx/Rx LEDs for the serial ports 
on the front panel, and 8 or 16 RJ45 serial port connectors on the 
rear panel. This makes the NPort® 5600 device servers suitable for 
standard 19-inch rack mounting, allowing you to simplify operational, 
maintenance, and administrative tasks.
Real COM/TTY Ports
Real COM/TTY drivers are provided to make the serial ports on the 
NPort® 5600 recognizable as Real COM ports by Windows, or Real 
TTY ports by Linux. In addition to supporting basic data transmission 
and reception, the NPort® drivers also support the RTS, CTS, DTR, 
DSR, and DCD control signals.
LED Indicators to Ease Your Maintenance Tasks
The System LED, serial Tx/Rx LEDs, and Ethernet LEDs (located 
on the RJ45 connector) provide a great tool for basic maintenance 
tasks, and help engineers analyze problems in the field. The LEDs not 
only indicate current system and network status, but also help field 
engineers monitor the status of attached serial devices.
Adjustable Termination and Pull High/Low Resistors
When using termination resistors to prevent serial signal reflection, 
it is important to set the pull high/low resistors correctly so that the 
electrical signal is not corrupted. Since no set of resistor values is 
universally compatible for all environments, the NPort® 5600 has DIP 
switches on the bottom panel for setting the termination and pull high/
low resistor values.
Mounting Plate
Serial Ports (50 bps to 921.6 Kbps, RJ45 connectors)
                                                NPort® 5610:
 RS-232
                                                NPort® 5630: RS-422/485
                                                NPort® 5650: RS-232/422/485
AC Power Input
100 to 240 VAC Input, 47 to 63 HZ
LCD Panel
Reset Button
Push Buttons
LED Indicators
System Status, Serial Tx/Rx
Ethernet 
RJ45 10/100 Mbps
AC Power Switch
Connection Cable
RJ45 to DB9 Cable 
(Optional Accessory)