Fujitsu BX400 S1 VFY:B4001SC020IN Data Sheet
Product codes
VFY:B4001SC020IN
Data Sheet
Fujitsu PRIMERGY BX400 S1 Blade Server
Page 3 / 6
http://ts.fujitsu.com/Primergy
Technical details
Enclosure
System unit type
6 U chassis for 19-inch rack, or floorstand version
Front bays
8 half height bays for server or storage blades
Midplane
High speed midplane with 3 fabrics
Rear bays
4 x for Connection Blades
4 x for PSU/fan modules
4 x for PSU/fan modules
Management Blades
1x hot-plug management blade as standard, redundant management blades as option
Fan configuration
Up to 3 hot plug, redundant rear fan units (2 fans per unit)
Power supply configuration
Up to 4x hot-plug power supply modules (1x as standard)
Operating panel
Operating buttons
On/off switch
ID button
ID button
Status LEDs
Power (amber / green)
System status (amber / yellow)
Identification (blue)
System status (amber / yellow)
Identification (blue)
Service display
ServerView Local Service Display for Blade (LSB)
ODD
1 - assinged to server blade by MMB control
USB ports
2 - assigned to server blade by MMB control
Management Blade
Type of Unit
BX900 MMB S1
LAN / Ethernet (RJ-45)
2 x 1Gb Ethernet
Service LAN (RJ45)
Dedicated Service LAN port for MMB (1Gb Ethernet)
Serial 1 (9-pin)
1 x RS-232-C
USB ports
2 x (at rear side of the system)
Dimensions / Weight
Floor-stand (W x D x H)
578 x 819 x 366 mm
Rack (W x D x H)
445 x 785 x 267 mm
Mounting Depth Rack
818 mm
Height Unit Rack
6 U
19” rackmount
Yes
Weight
Rack: up to 98 kg / Floorstand: up to 112.5 kg
Weight notes
Fully assembled
Actual weight may vary depending on configuration
Actual weight may vary depending on configuration
Rack integration kit
Included in Rack System
Electrical values
Max. input of single power supply
1200 W / 1785 W (100 V - 240 V)
Power supply configuration note
max. 4 PSU in n, n+1 or n+n redundancy configuration.
Power supply efficiency
92% (at 50% PSU load, CSCI “gold”)
Rated voltage range
100 V - 240 V
Rated frequency range
50 Hz - 60 Hz
Rated current max.
45 A / 22.5 A (100 V - 240 V)
Electrical value notes
Active power max. value depends on system configuration.
For details see Power Configuration Tool.
Power plug: non industrial type a connector (100V) e.g. NEMA 5-15P or 5-20P / industrial type b connector (230V)
e.g. IEC60309
For details see Power Configuration Tool.
Power plug: non industrial type a connector (100V) e.g. NEMA 5-15P or 5-20P / industrial type b connector (230V)
e.g. IEC60309
Environmental
Noise emission
Measured according to ISO 7779 and declared according to ISO 9296