Landis+Gyr Technology Inc. CWE-WALL2 User Manual

Page of 41
fåëí~ääáåÖ=íÜÉ=`ÉääåÉí=t~íÉê=båÇéçáåí
`ÉääåÉí=t~íÉê=båÇéçáåí=fåëí~ää~íáçå=dìáÇÉ
OJP
Connecting a Neptune Auto or Sensus Encoder Register with Screw Terminals
Remove terminal cover.
 
Use clean, disposable towels or rags to wipe the gel away 
from the terminals and screws. After the gel is removed, disconnect any wires 
connected to the terminals. Clean the terminals and screws again using Dow 
Corning OS-2 Silicone Cleaner or equivalent. Be careful not to lose any screws 
when disconnecting the wires or cleaning the screw terminals. 
If the cable to be connected to the screw terminals has been pre-stripped, proceed 
to step 3 below.
1
Using the #10 AWG position (second largest hole) on the 64-1919 wire 
stripper, remove 1.5 inches of external insulation from the cable.
Figure 2.1 64-1919 Wire stripper
2
Using the #22 AWG wire-stripping hole of 64-1922 tool, strip .5 inch of 
insulation from each of the three internal wires.
Figure 2.2 64-1922 Wire stripper
Do not damage the internal wire insulation when removing the
external insulation.