Landis+Gyr Technology Inc. ER6R1S4 User Manual

Page of 77
Draft
Landis+Gyr
Chapter 7 - Specifications 
User Guide
98-1723 Rev AB
75
Environmental
Mechanical
Regulatory Compliance
Table 7-6. Environmental Specifications
Parameter
Min
Max
Units
Notes
Storage temperature
-40
85
°C
Operating Temperature
-40
70
°C
Relative Humidity
0
95
%
Non-condensing
Table 7-7. 
Parameter
Value
Size
2.6 W x 5.6 L x 1.16 H inches, typical (excluding antenna)
Weight
2.4 ounces typical
Table 7-8. Regulatory Compliance 
Parameter
Comments
Cellular Radio
Meets Sierra Wireless design criteria in order to use the 
FCC ID of their existing modular approval.
ZigBee Radio
FCC CFR Title 47, part 15.247
Conducted Emissions
ANSI C12.1-2008 section 4.7.3.13 Test 27
FCC CFR Title 47, part 15 subpart A and B, class B
Radiated Emissions
ANSI C12.1-2008 section 4.7.3.13 Test 27
FCC CFR Title 47, part 15 subpart A and B, class B
Electrostatic Discharge Immunity
ANSI C12.1-2008 section 4.7.3.14 Test 28
IEC 61000-4-2 Level 4
Radiated RF Electromagnetic Field Immunity
ANSI C12.1-2008 section 4.7.3.12 Test 26
IEC 61000-4-3 Level x (15V/m)
Electrical Fast Transient/Burst Immunity
ANSI C12.1-2008 section 4.7.3.11 Test 25
IEC 61000-4-4 Level 4
Additional requirement of 4.4kV test voltage
Surge Immunity (Combination Wave)
ANSI C12.1-2008 section 4.7.3.3 Test 17
IEEE C62.41.2-2002 Category B
IEC 61000-4-5 Level x (6kV)
Surge Immunity (100 kHz Ring Wave)
ANSI C12.1-2008 section 4.7.3.3 Test 17
IEEE C62.41.2-2002 Category B
IEC 61000-4-12 Level x (6kV)
Surge Immunity (1 MHz Oscillatory)
ANSI C12.1-2008 section 4.7.3.11a Test 25a
IEEE C37.90.1-2002
IEC 61000-4-18 Level 3