If  it  is  impossible  to  avoid  metallic  objects  in  the  beam,  the  accuracy  can  be  increased  by 
adding intentionally reflectors or by using microwave absorbing materials to avoid the main 
reflectors to enter the radar. Please consult ISG support team for guidelines on how to do this.  
NOTE!  Some  types  of  fluorescent  light  tubes  emit  significant  electromagnetic  noise. 
Placement  of  the  TrackMan™  Radar  Unit  nearby  such  types  of  light  tubes  will  have  a 
negative influence on the tracking capability of the TrackMan™ system. 
 
  
3.2  Step-by-step setup 
 
In order for the system to function properly, it has to be set up in the correct way, and in the 
correct order: 
1.
 
Place the RU and DU where you want them roughly to be. Turn on the DU 
2.
 
Pull out the two legs of the RU until you hear a click. This indicates that the legs are 
safely  fastened  in  their  sockets.  If the legs  are  at  different  lengths,  don’t be alarmed. 
This is merely a result from the last time the unit was operated. 
3.
 
Tip  out  the  orange  leg  on  the  back  of  the  RU  about  120  deg  until  it  snaps  in  place. 
Now the leg should be locked in place. 
4.
 
Align the front of the RU roughly in the desired ball flight direction. 
5.
 
Connect the AC adaptor or the battery to the RU. 
6.
 
Connect  the  USB  cable to  the RU  and  the  DU, and  make  sure  the power  LED  turns 
ON (the RU does not use any power until the USB is connected) 
7.
 
Start the TrackMan™ application software. 
 
The final horizontal alignment happens from within the TrackMan™ application software. 
 
Depending on type of DU being used, it might be required to place the DU on a table to make 
sure moisture does not enter the DU. Please check with the guidelines for the DU. 
 
If  it  is  raining,  make  sure  that  the  DU  and  the  AC  adaptor  is  placed  under  cover.  To  avoid 
malfunction, make sure that the DU is kept clean and dry.