C-Com Corporation 56AZBT User Manual

Page of 55
5.10 S-Registers 
The S-Registers are summarized in the following table. Registers denoted with a * may be customized using the 
PTT Wizard Tool.
 
Factory defaults
 
Factory defaults are stored in the Windows OS registry. They are loaded at initialization time or by AT commands 
(&F,Z). In addition the designated default profile (as specified by the Yn command) is subsequently loaded.
 
The defaults shown are of the Smart Link factory settings 0 and 1.
 
 
 
S-Register Summary
 
Note: This S-register List is not to be used as is by End Users and in End User’s manuals.
 
For end users the contents of the first 24 S-registers should suffice.
 
S#
 
Function
 
Range
 
Units
 
PW
 
Default
 
AT Command
 
S0
 
Rings to Auto-Answer
 
0-255
 
rings
 
 
 
0
 
A
 
S1
 
Ring Counter
 
0-255
 
rings
 
 
 
0
 
 
 
S2
 
Escape Character
 
0-255
 
ASCII
 
 
 
43
 
 
 
S3
 
CR Character
 
0-255
 
ASCII
 
 
 
13
 
 
 
S4
 
LF Character
 
0-255
 
ASCII
 
 
 
10
 
 
 
S5
 
BS Character
 
0-255
 
ASCII
 
 
 
8
 
 
 
S6
 
Wait Time for Dial Tone
   
(Also wait before Blind Dialing)
 
2-255
 
s
 
*
 
2
 
D
 
S7
 
Wait Time for Carrier
 
1-255
 
s
 
*
 
60
 
D
 
S8
 
Pause Time for Dial (,)
 
0-255
 
s
 
 
 
2
 
D
 
S9
 
Carrier Detect Response Time
 
1-255
 
0.1s
 
 
 
6
 
 
 
S10
 
Carrier Loss Disconnect Time
 
1-255
 
0.1s
 
*
 
128