Inscape Data Co. AGNVC110W User Manual

Page of 51
NVC100/110 User’s Manual 
 
 
33
33
33
33 of 
 of 
 of 
 of 51
51
51
51  
-  Type Selection: Select sensor type. There are two types of sensors 
Normal Open: “floating” in normal situations, non-floating means an alarm condition. 
Normal Close: “non-floating” in normal situations, floating means an alarm condition. 
 
Video Capture Condition
: Sets the condition of the video recording and transmission via FTP or 
E-mail. The NVC100/110 supports 3 types of conditions: 
1. Sensor: When at least one of the sensors detects an alarm condition. 
2. Motion-detected: When motion is detected from the video channel. 
3. Periodic: Video is recorded during pre-defined time zone. 
 
The above 3 conditions are mutually independent in operation. 
# Sensor Select: Select the sensor that triggers video capture. 
# Motion Detection Select: Select the video channel that triggers video capture. 
# Periodic Transfer Select: Set the pre-defined time for periodic video capture. 
 
Captured Video Transmission
: Select a way of sending captured video. You can send 
captured video through FTP or E-mail, or both.   
-  FTP is sent to the FTP Server. Refer to 
[Section 5.3.]
 
E-mail is sent to the Recv E-mail address. Refer to 
[Section 5.3.] 
If the FTP server is not properly assigned in Network Configuration mode, the 
NVC100/110 ignores the video transmission by FTP   
 
 
 
Captured video data for E-mail consists of intra frames only in consideration of the
limited storage space for E-mail account.    FTP data contains entire video frames
Video for periodic recording is sent only to the FTP server.