Testing the apC/8X Installation
apC/8X Technical Manual
B
-
17
Monitor Menu
The monitor menu will display access reports and card swipes that are also 
sent to the host computer.
If F7 is selected, the sub-menu allows you to control the monitor point 
message content.
Table B.7: Monitor Menu Function Keys and Actions
Function 
Key
Action
F1
Display Monitor Help
F2
Return to the Main Menu
F3
AccRpt - Display access message sent to the host
F4
Swipe - Display card swipes
F5
NoAcc - Do not display access messages to the host
F6
NoSwipe - Do not display card swipes
F7
Mpts - Display selected messages about monitor point changes
Table B.8:
F1
Display Help
F2
Return to Monitor menu
F3
Display all MPT state changes
F4
Display equipment related reports: cabinet tamper, power fault, or 
host offline
F5
Display access alarm reports: tamper, reader offline, etc.
F6
Display supervised input monitor point state change reports
F7
Do not display monitor point state change reports
F8
Initialize all monitor points to secure