Programming Ports DIP Switch Used for 
Muting Option 
Setting the Mute Option 
Individual Muting (default) 
Each Solo microphone will mute only itself when its mute button on the 
microphone is pressed.  If the mute button on the remote control is pressed, all 
microphones are muted (all mics will flash red LEDs).  In this master muted 
state, the individual mute buttons on the microphones themselves will be 
ignored, to prevent accidental un-muting.  To disengage master mute, the mute 
button on the remote control should be pressed again.  All microphones will 
return to their prior state.  DIP switch #5 is OFF.   
Tabletop Microphone Master Mute 
Solo wearable and XLR type microphones will mute only themselves only when 
the mute button on the microphone is pressed.  Pressing the mute button on 
any Solo Tabletop microphone, will mute all active tabletop microphones; 
wearable and XLR type microphones will remain unaffected by the tabletop 
mute.  Pressing any tabletop microphone mute button will disengage the 
tabletop mute.   If the mute button on the remote control is pressed, all 
microphones are muted (all mics will flash red LEDs).  In this master muted 
state, the individual mute buttons on the microphones themselves will be 
ignored to prevent accidental un-muting.  To disengage master mute, the mute 
button on the remote control should be pressed again.  All microphones will 
return to their prior state. DIP switch #5 is ON. 
Page 20 
Installation  Guide 
Programming Port Settings for Multiple 
Fusion Systems  
There are two settings that must be adjusted when more than one Fusion 
system is used within a 100’ (30.5 m) foot range:  frequency and transmit power 
level.  These settings will enable several Fusion systems to be used near each 
other, but not interfere with each other.  Interference between systems can 
cause occasional audio noise and signal dropouts on affected systems.  Building 
conditions may influence this distance.     
NOTE:  Even using the settings below, the 8- Microphone Fusion System 
requires 40 feet (12.2 m) between systems
.     
Setting the Transmit Power Level for Multiple Fusion Systems 
In confined settings where multiple Fusion systems are used, or where audio 
interference is likely, it may be necessary to reduce the transmit power levels.  
The transmit power level between the Microphone and Charger Base can be set 
to the following three levels: 
• 
Highest power level (default) – 100 feet (30.5 m) maximum operating 
distance between Microphone and Charger Base DIP Switches #1 and #2 
are OFF.   
• 
Medium power level – 30 feet (9 m) maximum operating distance between 
Microphone and Charger Base.  DIP Switch #1 is ON and DIP Switch #2 is 
OFF.   
• 
Lowest power level – 8 feet (2.4 m) maximum operating distance between 
Microphone and Charger Base. DIP Switch #2 is ON and DIP Switch #1 is 
OFF.   
Frequency Settings 
Frequency should be alternated to different frequency ranges, A and B.  So an 
example of five conference rooms in a row would be configured: 
 
 
  
To configure the Fusion to frequency mode A, Dip Switch #3 is ON and DIP 
Switch #4 is OFF.  Frequency mode B - Dip Switch #4 is ON and DIP Switch #3 
is OFF.   
Conference 
Room 
1 2 3 4  5 
Frequency 
A B A B A 
Conference 
Room 
1 2 3 4  5 
Frequency 
A B A B A 