ACM8068 module is used as DCE (Data circuit-terminating equipment). 
However to let customer connect DCE-DTE, the signal naming is provided 
here as DTE (Data terminal equipment) signal definitions.     
 
38 
VBAT 
Power input positive, input 
voltage is limited to 3.5V ~ 4.5V 
39 
VBAT 
Power input positive, input 
voltage is limited to 3.5V ~ 4.5V 
40 
GPO1 
General purpose I/O 
41 
NETLIGHT 
 
42 
DCD 
UART0 DCD 
43 
DTR 
UART0 DTR 
44 
RTS 
UART0 RTS 
45 
CTS 
UART0 CTS 
46 
GPIO 
General purpose I/O 
47 
SIM_PRESENCE 
SIM interface 
48 
GND 
Ground