If you experience a problem with Speedway Revolution, this brief chapter 
presents a few suggestions to correct the issue. 
Returning to the Factory Default Configuration 
If you are experiencing a problem with the reader and are having difficulty 
pinpointing the cause, it is useful to return the reader to a known state. We 
recommend resetting to the factory default configuration. Then try your reader 
again. 
!
 
Important
Factory Default Configuration Restore returns the reader 
configuration to its default state. It leaves any custom applications installed in 
the CAP intact. To restore the reader to its default state and remove any CAP 
contents, use Factory Default Restore. See the 
Warning
 on page 28. 
There are two ways to return Speedway Revolution to its factory default 
configuration: issuing an Rshell command or pushing the Factory Default Reset 
(FDR) button on the device. 
To use Rshell to return the reader to its factory default configuration 
and leaving CAP intact: 
1.  At the Rshell prompt, enter the following command: 
config image default 
When the command completes successfully, the reader automatically 
reboots and returns to the login prompt. 
2.  Log in to the reader. The reader is now running with the factory default 
configuration. CAP applications are intact. 
To use the FDR button on the reader to restore to its factory default 
configuration: 
1.  Using an object with a sharp tip, a paper clip or probe, press and hold the 
FDR button on the back while the reader power is on.  
2.  Continue holding the FDR button. Wait for 3 seconds after the Power LED 
turns off.  
3.  Release the FDR button when the LED blinks red once. The reader will 
boot up normally in the factory default configuration. 
 
 
 
 
 
 
 
 
Figure 5.1 Factory default reset button 
 
Warning: 
Pressing the FDR button for longer than 3 seconds can cause a factory 
default restore to occur. The factory default restore removes the reader’s custom 
Factory Default 
Restore button 
Insert and hold sharp point here for 
3 seconds. Release before 10 