6
 
Operating Frequency 1500 MHz and Higher (MPE = 10 W/m
2
  
Transmitter Power 
Transmitter Power 
Transmitter Power 
Transmitter Power 
  
0.25 Watts 
0.5 Watts 
1 Watt 
2 Watts 
Antenna 
  
Minimum 
  
Minimum
  
Minimum
  
Minimum
Gain  EIRP Distance EIRP Distance EIRP Distance EIRP Distance 
(dBi)  (Watts) (Meters) (Watts)
(Meters) (Watts)
(Meters) (Watts) (Meters) 
0  0.25 >0.20 0.50 >0.20 1.00 >0.20 2.00 >0.20 
2  0.40 >0.20 0.79 >0.20 1.58 >0.20 3.17 >0.20 
5  0.79 >0.20 1.58 >0.20 3.16 >0.20 6.32  0.22 
10  2.50 >0.20 5.00 >0.20 10.0 0.28 20.0 0.40 
15  7.91 0.25 15.8 0.35 31.6 0.50 63.2 0.71 
20  25.0 0.45 50.0 0.63 100.0 0.89 200.0 1.26 
25 79.1 0.79 
158.1 
1.12 
316.2 1.59 632.5 2.24 
30  250.0 1.41 500.0 1.99 1000.0 2.82 2000.0 3.99 
 
Operating Frequency 340 - 400 MHz (MPE = 2.27 W/m
2
  
Transmitter Power 
Transmitter Power 
Transmitter Power 
Transmitter Power 
  
0.25 Watts 
0.5 Watts 
1 Watt 
2 Watts 
Antenna 
  
Minimum 
  
Minimum
  
Minimum
  
Minimum
Gain  EIRP Distance EIRP Distance EIRP Distance EIRP Distance 
(dBi)  (Watts) (Meters) (Watts)
(Meters) (Watts)
(Meters) (Watts) (Meters) 
0  0.25 >0.20 0.50 >0.20 1.00 >0.20 2.00  0.26 
2  0.40 >0.20 0.79 >0.20 1.58 0.24 3.17 0.33 
5 0.79 
>0.20 
1.58 
0.24 3.16 0.33 6.32 0.47 
10  2.50 0.30 5.00 0.42 10.0 0.59 20.0 0.84 
15  7.91 0.53 15.8 0.74 31.6 1.05 63.2 1.49 
20  25.0 0.94 50.0 1.32 100.0 1.87 200.0 2.65 
25 79.1 1.66 
158.1 
2.35 
316.2 3.33 632.5 4.71 
30  250.0 2.96 500.0 4.19 1000.0 5.92 2000.0 8.37 
 
MAINTAIN A SAFE PERSONAL DISTANCE FROM THE ANTENNA WHILE 
TRANSMITTER IS OPERATIONAL. 
 
FAILURE TO MAINTAIN A SAFE PERSONAL DISTANCE FROM THE 
ANTENNA MAY RESULT IN PERSONAL INJURY. 
3.0 
PREPARATION FOR USE 
 
3.1 Unpacking 
Carefully remove the transmitter from the shipping container and make sure all listed 
furnished items are included (Section 1.5).  Inspect all items for damage.  If any item is 
omitted from the shipment or appears damaged, contact Dyplex or AMP with detailed 
description of problem.