Specifications
PHYSICAL
ELECTRICAL
Height
46mm (1.81")
Operating Voltage
2-3.6V DC
Width
32mm (1.25")
Input Voltage
3.3V
Depth
5.5mm (0.21")
Standing Current
8mA, 28.5mA burst
Enclosure Material
N/A
Shield thickness
0.016 inch thick
Mounting Method
Soldering
Shield material
Brass, nickel plated
Temperature Ratings
Operating:
0°C to 50°C (32°F to 122°F)
Storage/ Transport:
-55°C to 85°C (-67°F to 185°F)
FCC/IC Statements
FCC ID UI6-ZRX
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by the party r
esponsible for compliance could void the user’s authority to operate the
equipment.
To Comply with FCC/IC RF exposure limits for general population/uncontrolled exposure, the antenna(s) used for this transmitter must
be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction
with any other antenna or transmitter.
be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction
with any other antenna or transmitter.
IC: 6706A-ZRX
This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
undesired operation of the device.
Cet appareil est conforme avec les norme(s) exemption de licenc
es RSS d’Industrie Canada. Opération est sujet au deux conditions
suivantes. (1) Cet appareil ne peut causer d'interférences, et (2) cet appareil doit accepter toute interférence, y compris les
interférences qui peuvent causer un mauvais fonctionnement de l'appareil.
interférences qui peuvent causer un mauvais fonctionnement de l'appareil.
OEM Responsibilities to comply with FCC and Industry Canada Regulations
The ZRF Module has been certified for integration into products only by OEM integrators under the following conditions:
1.
The antenna(s) must be installed such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and
all persons at all times.
all persons at all times.
2.
The transmitter module must not be co-located or operating in conjunction with any other antenna or transmitter. As long as the two
conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing
their end-product for any additional compliance requirements required with this module installed (for example, digital device emissions,
PC peripheral requirements, etc.).
conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing
their end-product for any additional compliance requirements required with this module installed (for example, digital device emissions,
PC peripheral requirements, etc.).
IMPORTANT NOTE: In the event that these conditions cannot be met (for certain configurations or co-location with another transmitter), then the
FCC and Industry Canada authorizations are no longer considered valid and the FCC ID and IC Certification Number cannot be used on the final
Do not mount Wireless Devices using ZRF on or near metal objects (HVAC, I Beams, etc) or
electrical devices (motors, high voltage switching, etc) as they can interfere with the wireless
signals
signals