7.7.7 APPLYING CONFIGURATION CHANGES
To apply new or changed configuration to RFP devices, select one or more RFP entries from the table
and click the
and click the
Send Configuration option in the task bar.
Note: You must close the Detail Data window to apply configuration
changes to an RFP. If the Detail Data window is open, the
Send
Configuration option is disabled.
The OM Configurator displays the
Protocol settings dialog window.
The settings in the
Protocol settings dialog are preset to the values used for the Scan operation or the
last
Send Configuration operation. If the values are correct, click OK to transfer the data to the RFP
device.
Before sending the data, the system performs a check on mandatory parameters and the validity of
some parameter values. If this check fails, an error is reported in the Info console.
some parameter values. If this check fails, an error is reported in the Info console.
The system displays a message in the Info console window indicating success or failure of the data
transfer operation for each RFP.
transfer operation for each RFP.
If data is transferred successfully, the OM Configurator displays a checkmark beside the row for the
corresponding RFP.
corresponding RFP.
The OM Configurator attempts data transfer three times (two seconds apart) before reporting an error.
Depending on the network environment and current RFP status, the data transfer may fail in rare cases.
If a failure to transfer data occurs, click the
Depending on the network environment and current RFP status, the data transfer may fail in rare cases.
If a failure to transfer data occurs, click the
Send Configuration option again to re-initialize the data
transfer.
If the data transfer fails, the OM Configurator displays an “X” beside the row for the corresponding RFP.
7.7.8 FACTORY RESET
RFPs are protected against unauthorized configuration changes by user authentication (user and
password), which are also used to configure the OMM via web service or OMP.
password), which are also used to configure the OMM via web service or OMP.
To reset a RFP’s configuration, select the RFP entry in the table and click the
Factory Reset option in
the task bar. This option is only enabled when a single RFP entry is selected. The option is disabled if
multiple RFPs are selected.
multiple RFPs are selected.
The system displays the
Factory reset settings dialog window. Set the correct login data (user and
password) and RFP proxy address (if required). The system auto-fills the fields with the values used for
previous
previous
Scan, Send Configuration or Factory Reset operations.
If the specified login (“omm”/”omm”) does not work and the login credentials of the last system the RFP
was used with are unknown, you can reset the RFP to factory settings by sending a cookie string to the
OpenMobility manufacturer support and entering the received reset key. The OM Configurator copies
the cookie string to the clip board.
was used with are unknown, you can reset the RFP to factory settings by sending a cookie string to the
OpenMobility manufacturer support and entering the received reset key. The OM Configurator copies
the cookie string to the clip board.
7.7.9 SAVING AND LOADING AN RFP LIST
You can save the configuration of one or more RFPs to a RFP configuration file. Select the RFP entries
in the table and click the
in the table and click the
Save RFP Config option in the task bar. (Note that if the Detail Data window is
active, the
Save RFP Config option is disabled.)