Tripp Lite SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch SU6000RT4UHV User Manual

Product codes
SU6000RT4UHV
Page of 7
 
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
Model #: SU6000RT4UHV
SmartOnline 6kVA On-Line Double-Conversion UPS, 4U Rack/Tower, 200-240V NEMA outlets
 
Highlights
6kVA / 6000VA / 5400 watt on-line double-conversion 4U rack/tower UPS with
0.9 output power factor 
200/208/220/230/240V +/-2% output at 50/60Hz, high efficiency economy
mode option
Hot-swappable power and battery modules; Low profile housing with reduced
21 in / 53cm mounting depth
USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card
options
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
NEMA L6-30P input (3 wire); L6-30R & L6-20R outputs
Description
Tripp Lite SU6000RT4UHV 6000VA / 6kVA / 5400 watt online, double-conversion UPS system offers complete power protection for critical server,
network and telecommunications equipment in a single 4U rack/tower compatible housing. Full-time active power conditioning provides clean,
continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents
unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU with manual bypass switch supports
hot-swappable whole UPS replacement with no interruption to connected equipment. Single all-in-one rack / tower housing installs in only 4 rack
spaces (4U) with a maximum installed depth of only 20.7 in. / 52.6cm. Maintains full-time sine wave output within 2% of selectable
200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional
BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power
outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then
resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other
hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU
heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels,
self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional SNMP/Web and contact-closure communications card
accessories available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows
and Mac OS X. Included PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of
connected systems as UPS batteries become depleted. Included software packages include PowerAlert Local, PowerAlert Network Shutdown Agent
and PowerAlert Network Management System for complete support for a wide variety of application types. Supports Emergency Power Off (EPO)
via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of
control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower
configurations. L6-30P input plug. UPS supported outlets include two L6-30R and two L6-20R outlets. External battery packs are field replaceable
and hot swappable. 2 year warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.
Features
Tripp Lite SU6000RT4UHV 6000VA / 6kVA / 5400 watt online, double-conversion UPS system in a single 4U rack/tower compatible housing
(at 208V nominal, output is limited to 4992 watts)