Allied Telesis UTP to single-mode (40km) fibre AT-MC103LH Leaflet

Product codes
AT-MC103LH
Page of 2
Launch Power (dBm)
Receive Power (dBm)
Cable Optical
Min.
Typical
Port Type  (Connector)
Distance
Frequency
Max.
Avg.
Min.
Sensitivity
Sensitivity
Saturation
10T UTP Copper
100m
102 Coax Copper
185m
10FL MMF
2km 850nm
-10.0
-12.0
-15.0
-41.4
-43.0
-7.6
10FL SMF
15km
1310nm
-17.0
-21.0
-23.0
-41.5
-45.0
-14.0
100TX UTP Copper
100m 
100FX MMF
2km
1310nm
-14.0
-16.8
-19.0
-31.8
-34.5
-14.0
100SX MMF
300m
850nm
-10.0
-12.0
-15.0
-41.4
-43.0
-7.6
100FX SMF (15km)
15km
1310nm
-8.0
-11.5
-15.0
-31.0
-31.0
-8.0
100FX SMF (40km)
40km
1310nm
0.0
-3.0
-5.0
-35.0
-38.0
0.0
100FX SMF (75km)
75km
1310nm
0.0
-2.0
-4.0
-37.0
-37.0
-3.0
100FX SMF (100km)
100km
1550nm
0.0
-1.5
-3.0
-37.0
-37.0
-3.0
1000T UTP Copper
100m
1000SX MMF
220-550m
850nm
-4.0
-7.0
-10.0
-16.0
-16.0
0.0
1000LX SMF (10km)
10km
1310nm
-3.0
-6.3
-9.5
-20.0
-20.0
-3.0
1000LX SMF (20km)
20km
1310nm
0.0
-1.5
-3.0
-24.0
-24.0
-3.0
1000LX SMF (50km)
50km
1550nm
0.0
-2.5
-5.0
-24.0
-24.0
-3.0
1000LX SMF (70km)
70km
1550nm
5.5
2.8
0.0
-24.0
-24.0
-3.0
ORDERING INFORMATION
AT-MC103XL-xx
UTP to single-mode (15km) fibre
AT-MC103LH-xx
UTP to single-mode (40km) fibre
AT-MC103SC/FS3-xx
UTP to single-mode (75km) fibre
AT-MC103SC/FS4-xx
UTP to single-mode (100km) fibre
AT-MC104XL-xx
Multi-mode fibre to single-mode (15km) fibre
AT-MC104LH-xx
Multi-mode fibre to single-mode (40km) fibre
AT-MC104SC/FS3-xx
Multi-mode fibre to single-mode (75km) fibre
AT-MC104SC/FS4-xx
Multi-mode fibre to single-mode (100km) fibre
Where xx =
10 for U.S. power cord
20 for no power cord
30 for U.K. power cord
40 for Australian power cord
50 for European power cord
AT-MC100 Series, Fast Ethernet Media Converters
STATUS INDICATORS
Front Panel
Power
Indicates power is applied to the
converter
Link (2)
Indicates a valid receive link exists
Receive (2)
Indicates valid data being received by
converter
Normal/Test
Fibre test or normal operation
PACKET TRANSMISSION
CHARACTERISTICS
Round Trip Delay
0.4µs Maximum
Bit Error Rate (BER) <10
-12
TWISTED PAIR INTERFACE
Min.
Typical Max.
UTP Differential 
Output 
Voltage 
950mv 980mv 1050mv
Overshoot Voltage 
4% 
5%
Single Amplitude 
Symmetry 0.98 
1.0062 
1.02
Rise and Fall Time:
Rise 
3.0ns 4.6ns 5.0ns
Fall 
3.0ns 4.2ns 5.0ns
Rise and Fall Time 
Symmetry 0.4ns 
0.5ns
POWER CHARACTERISTICS
External Power Supply
100-240V AC, 50-60Hz
+/-3%
Input Supply Voltage
12vDC +/-5%
Max Current
0.5
Power Consumption 
6W
ENVIRONMENTAL SPECIFICATIONS
Operating Temp
0°C to 40°C 
(32°F to 104°F)
Storage Temp.
–20°C to 80°C
Relative Humidity 
5% to 95% non-condensing
Operating Altitude
0 to 10,000 feet
PHYSICAL CHARACTERISTICS
Dimensions
10.5cm x 9.5cm x 2.5cm
(4.12” x 3.75” x 1.0”)
Weight
294g (10.4oz)
ELECTRICAL/MECHANICAL
APPROVALS
EMC
FCC Class A
Safety compliant
UL-Cul, CSA/CSA, NRTL,
TUV, CE compliant
European Headquarters
|
Via Motta 24
|
6830 Chiasso
|
Switzerland
|
T: +41 91 69769.00 
|
F: +41 91 69769.11
www.alliedtelesyn.com
© 2004 Allied Telesyn International Corp. All rights reserved. Information in this document is subject to change without notice.
All company names, logos and product designs that are trademarks or registered trademarks are the property of their respective owners.
Part Number 617-00340-00 Rev. C