Input circuit breaker
10A
UPS Input cord length
(ft.)
6
UPS Input cord length
(m)
1.8
Recommended
Electrical Service
15A 120V
BATTERY
Full load runtime
(minutes)
2.5 min. (825w)
Half load runtime
(minutes)
9 min. (413w)
DC system voltage (VDC)
24
Battery recharge rate
(included batteries)
Less than 3.5 hours from 10% to 90%
VOLTAGE REGULATION
Voltage regulation
description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
Overvoltage correction
Input voltages between 128 and 147 are reduced by 12%
Undervoltage correction
Input voltages between 93 and 107 are boosted by 14%
Severe undervoltage
correction
Input voltages between 75 and 92 are boosted by 30%
LEDS ALARMS & SWITCHES
LED Indicators
Front panel LCD display
Front panel LCD display
Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and
replace battery status; LCD screen rotates for rack/tower viewing
Alarms
Audible alarm indicates power-failure and low-battery conditions
Alarm cancel operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD
brightness
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
420
UPS AC suppression
response time
Instantaneous
UPS Dataline
suppression
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Installation form factors
supported with included
accessories
4 post 19 inch rackmount (mounting kit included); 2 post 19 inch rackmount (mounting kit included); Tower
Included mounting
accessory description
Pair of mounting ears enable tower and 2-4 post rackmount installation