RDa
SERVER CABINET RDA
DESCRIPTION, PURPOSE OF USE
• 19‘‘ free-standing cabinet with IP 30 protection
• Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than
• Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than
800 mm)
• Cabinet construction:
– welded steel frame with possibility to mount metal covers and side module
– glass door: safety hardened, thickness 4 mml
• Max. permissible load of the door is 20 kg.
• Min. thickness of the surface finish is 65 µm.
• These cabinets are intended for installation of data and telecommunication devices and
– welded steel frame with possibility to mount metal covers and side module
– glass door: safety hardened, thickness 4 mml
• Max. permissible load of the door is 20 kg.
• Min. thickness of the surface finish is 65 µm.
• These cabinets are intended for installation of data and telecommunication devices and
their distribution systems.
• The frame of the cabinet and all the removable parts (side and rear covers, doors…) are
connected with earthing cables that have to be properly fi xed and inserted into connectors
during all the time when using the cabinet.
during all the time when using the cabinet.
• There is one M8 screw placed on the bottom part of the cabinet as an earthing main point.
• Cable openings covered with breakout-type blanking panels are placed in the top and the
• Cable openings covered with breakout-type blanking panels are placed in the top and the
bottom part of the cabinet.
OPERaTION CONDITIONS
• Operation environment:
– industrial, office
– the cabinet is not intended for outdoor installations and for installations in environment
– industrial, office
– the cabinet is not intended for outdoor installations and for installations in environment
that can influence negatively the functionality of the cabinet and the mounted devices
(e.g. environment with danger of explosion)
(e.g. environment with danger of explosion)
• Must be protected against:
– mechanical damage
– improper manipulation
– a different usage than the cabinet is intended for
• Improper manipulation is especially:
– overloading (maximum recommended load exceeding)
– device installation that can influence negatively operation and function of the cabinet or
– mechanical damage
– improper manipulation
– a different usage than the cabinet is intended for
• Improper manipulation is especially:
– overloading (maximum recommended load exceeding)
– device installation that can influence negatively operation and function of the cabinet or
the installed equipment
– change of the construction or design of the cabinet
INSTallaTION OF THE CaBINET
• To ensure the maximal recommended load, it is necessary to distribute the load equally.
• Place the cabinet on a flat floor and compensate an eventual small roughness with the
• Place the cabinet on a flat floor and compensate an eventual small roughness with the
nivelation feet.
• To avoid dust penetration in a case where cables lead through some of the cable openings,
it is possible to seal it using a blanking panel with a brush (which is a part of the cabinet
supply) or a protective plastic frame
supply) or a protective plastic frame
ENVIRONMENT PROTECTION
• All parts are made of recyclable materials and after its discard, it is necessary to dispose the
cabinet according to valid regulations.
CERTIFICaTE aND CONFORMITY
• This product is fully in accordance with ČSN eN 62208 (357040), (eN 62208:2003),
(idt IeC 62208:2002).