12.1 Climatic
Internal circuitry provides automatic shutdown control to prevent the unit from operating above
or below the specified operating temperature range.
or below the specified operating temperature range.
12.1.1 Climatic: Operational
Operating temperature
-20°C to +55°C
NOTE: Upper temperature range can be extended under
certain operating conditions.
certain operating conditions.
Relative humidity
5 - 95%
Solar radiation
Not Applicable
Air pressure (altitude)
70 kPa to 106 kPa (-400 m to 3000 m)
12.1.2 Climatic: Storage and Transportation
Duration
24 months
Ambient temperature
-40
°
C to +85
°
C
Relative humidity
5% to 95%, non condensing (at 40
°
C)
Thermal shock
-50
°
C to +23
°
C, +70
°
C to +23
°
C; < 5 min
Altitude
-400 m to 15,000 m
12.2 Mechanical
12.2.1 Mechanical: Operational
Operational vibration, sinusoidal
3.0 mm disp, 2 to 9 Hz; 1 m/s
2
, 9 to 350 Hz
Operational vibration, random
0.1 m
2
/s
3
, 2 to 200 Hz
12.2.2 Mechanical: Storage and Transportation
Transportation vibration, packaged
ASTM D999
Drop, packaged
ASTM D775 method A, 10 drops
Shock, un-packaged
150 m/s
2