Method of Procedure 
Installation 
78 
RFN_3.1 Beta
 
on the network connection to the site controller, the SmartJack is incorrectly 
configured. Contact the service provider immediately to correct this situation. The 
SmartJack switch should be set so that -48V power does not pass through to the 
site controller.  
If this cable is locally manufactured, crimp the 8-pin connectors as shown in the 
following illustration. The wires should be routed straight through. Make sure that 
the conductor color is the same at both ends for each conductor of the cable. 
 
Figure 29 
T1 interface cable configuration 
4.5.2 
RFS to iDEN Interface 
To connect the RFS to the iDEN Interface, connect the NCU to the iSC-3 using 
an Ethernet Media Converter. The Ethernet Media Converter is shipped with 
other RadioFrame System equipment in its own container with all the cables 
necessary to install it. 
Connecting the NCU to the iSC-3 
1  Find these items in the shipping box: one MC15 Ethernet Media Converter, 
Allied Telesyn User Guide (contains all product specifications), four rubber 
feet, one AC-DC power adapter, one 10BaseT Ethernet cable (straight-
through RJ45-to-RJ45 CAT 5 cable), and one 10Base2 cable (50 ohm coaxial