RadioFrame Networks Inc MCRB10 User Manual
MC-Series System Installation & Testing
Introduction
4
RadioFrame Networks, Inc.
• What causes the problem to occur
• Any unusual circumstances contributing to the problem (i.e., loss of power)
• Any unusual circumstances contributing to the problem (i.e., loss of power)
1.4.2 Technical
Support
For support of RadioFrame Networks equipment, contact the RadioFrame Networks Technical
Assistance Center (TAC) at:
Assistance Center (TAC) at:
(US) 1-800-328-0847
1.4.3
Field Replaceable Unit (FRU) Policy
The MC-Series System has been designed so that Field Repairable Units (FRUs) can be
replaced to restore normal system operation as quickly as possible. RFN components are
individually tested prior to shipment. If RFN equipment should require service or repair, note the
following information, and then contact the RFN Technical Assistance Center at (800) 328-0847:
replaced to restore normal system operation as quickly as possible. RFN components are
individually tested prior to shipment. If RFN equipment should require service or repair, note the
following information, and then contact the RFN Technical Assistance Center at (800) 328-0847:
NOTE: Do not attempt to repair RFN equipment and components in the field.
NOTE: Always use a static grounding wrist strap before handling any chassis or RadioBlade.
• Include the serial numbers of the affected equipment.
• Give a clear return address, including:
• Give a clear return address, including:
- contact person,
- phone number, and an
- alternate contact person and phone number (if possible).
- phone number, and an
- alternate contact person and phone number (if possible).
• Securely package the FRU in its original shipping carton, if available. Otherwise, package in
a static protection bag in a well-padded carton.
Refer to section 8.6 FRU Replacement Procedures for replacing any of the following equipment.
For equipment not supplied by RadioFrame Networks, follow standard Nextel policies and
procedures for FRU replacement.
For equipment not supplied by RadioFrame Networks, follow standard Nextel policies and
procedures for FRU replacement.
Table 1
MC-Series System FRUs
P/N
Description
176-0840-xx
800 MHz MC Series iDEN 2-Port RadioBlade (RB) Transceiver
176-0870-xx
800 MHz RF Shelf
176-0535-xx RadioBlade
Transceiver
Shelf
(RBS)
176-0800-xx
MC-15 Airlink Interface Chassis (AIC)
176-0900-xx
MC-15 BTS Interface Chassis (BIC)
176-7570-xx Base
Processing
Card
(BPC)
176-7550-xx
Base Processing Card (BPC) with SPAM
176-7540-xx
Common RadioFrame Interface Card (CRIC)