RadioFrame Networks Inc MCRB10 User Manual

Page of 167
MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
98 
RadioFrame Networks, Inc.
 
Index 
Part Number 
Disconnect From 
To 
Type 
DAT_6 
111-0001-02 
BIC:  CRTC 10base2 - ISC 
ISC 1:  10B2-1 
COAX 
CLK_1 
111-0001-02 
BIC:  ERTM 5MHz/1PPS IN 
ISC 1:  SITE REF OUT 1 
COAX 
* Remove both ends of this cable and keep it for the replacement BIC. 
 
Remove the chassis from the rack, and package it for shipment. 
Remove the 4 front mounting screws from the front of the unit (shown with arrows). 
 
 
Figure 31 
Front view of BIC 
Mount the replacement chassis.  
While supporting the chassis, slide the chassis into the cabinet mounting position. Secure the 
chassis to the cabinet mounting rails using the four mounting screws provided with the unit. 
Tighten the screws to 4.5 Nm (40 in-lb).  
Reconnect the cabling to the replacement chassis as defined in Step 2.  
Use the SMA torque wrench for all SMA connectors. 
Using the breakers on the PDU, turn up the BICAIC, and RBS 1 (and RBS 2 and RBS 3 if 
present), and then verify that the components are operational before proceeding. 
Wait approximately 3 minutes for the following indicators: 
• 
RBS:  The STATUS LED for each group will light green in this order: A, B, and then C.  
• 
RBS:  The RADIOBLADE STATUS LEDs will light red and then green for each present 
RadioBlade. If no RB is present, the LED will not light. To verify the contents of the RBS, 
pull out the shelf (powering off is not required) and inspect the RadioBlades and their 
respective status LEDs. Reinsert the RBS. To do this, press up on one side rail locking 
arm and press down on the other side rail locking arm, and then push the unit into the 
rack (see the following illustration). 
• 
BIC CRIC and AIC CRIC:  The POWER and STATUS LEDs will light red and then green. 
All other BIC and AIC card LEDs will light green. 
 
  
BPC   
BIC 
 
CRIC