MC-Series System Installation & Testing 
Final Checkout and Commissioning 
RadioFrame Networks, Inc.
  
49 
Using the breaker on the PDU and the power switch on the front of the EAS, turn up the EAS
and then verify that it is operational before proceeding. For more information, refer to the 
Motorola document Gen 3 Site Controller System Manual, 68P80801E30-O
Using the breaker on the PDU and the power switch on the front of the secondary iSC-3, turn 
up the secondary iSC-3, and verify that it is operational before proceeding. For more 
information, refer to the Motorola document Gen 3 Site Controller System Manual, 
68P80801E30-O
Using the breaker on the PDU, turn up the CSU
Configure the CSU according the manufacturer's documentation and Nextel standards.  
Using the breaker on the PDU, turn up the BICAIC, and RBS 1, and then verify that all three 
components are operational before proceeding. 
Wait approximately 3 minutes for the following indicators: 
• 
RBS:  The STATUS LED for each group will light green in this order: A, B, and then C.  
• 
RBS:  The RADIOBLADE STATUS LEDs will light red and then green for each present 
RadioBlade. If no RB is present, the LED will not light. To verify the contents of the RBS, 
pull out the shelf (powering off is not required) and inspect the RadioBlades and their 
respective status LEDs. Reinsert the RBS. To do this, press up on one side rail locking 
arm and press down on the other side rail locking arm, and then push the unit into the 
rack (see the following illustration). 
• 
BIC CRIC and AIC CRIC:  The POWER and STATUS LEDs will light red and then green. 
All other BIC and AIC card LEDs will light green. 
Using the breaker on the PDU, turn up RF Shelf 1, RF Shelf 2, and RF Shelf 3 and then 
verify that each RF shelf is operational before proceeding. 
The POWER and ALARM LEDs on the front of each RF shelf will light green. 
 
 
locking arm 
locking arm