RadioFrame Networks Inc MCSERIES10 User Manual

Page of 152
MC-Series System Installation & Testing 
Appendix E:  Tx / Rx Curves 
RadioFrame Networks, Inc.
  
125 
6Appendix E 
Tx / Rx Curves 
 
The TX filter frequency response is shown in the following illustration. 
CH1 S 12  
log MAG
10 dB/
REF 0 dB
    START  806.000 000 MHz
STOP  870.000 000 MHz
 
  
  
 
LARK PN 4C806-812 SN 23639-03
 
C?
 
 
 
 
 
 
 
PRm
 
 
20 Jul 2004  13:32:09
1
2
3
4
4_:-60.167 dB
  840.566 401 MHz
               
1_:-1.7807 dB
 851 MHz 
2_:-.4818  dB
 870 MHz 
3_:-59.574 dB
 847.425 MHz 
 
 
Figure 28 