2.5.9.4
Transmit Filter Specification
Value
Parameter
1
Condition
Min
Max
Unit
Pass Band
851.0125
869.9875
MHz
Pass Band Insertion
Loss
Loss
Referenced to a 50 ohm
impedance
impedance
2.0
dB
Pass Band Ripple
Referenced to a 50 ohm
impedance
impedance
-0.5 +0.5 dB
Stop Band
Attenuation
Attenuation
Referenced to a 50 ohm
impedance
impedance
-60
dBc
Note 1: Unless otherwise stated, all values are referenced to the top of the rack.
Refer to Appendix E for filter curve.
2.5.9.5
Receive Filter Specifications
Value
Parameter
1
Condition
Min
Max
Unit
Pass Band
806.0125
824.9875
MHz
Pass Band Insertion
Loss
Loss
Referenced to a 50 ohm
impedance
impedance
1.0
dB
Pass Band Ripple
Referenced to a 50 ohm
impedance
impedance
-0.5 +0.5 dB
Stop Band
Attenuation
Attenuation
Referenced to a 50 ohm
impedance
impedance
-60
dBc
Note 1: Unless otherwise stated, all values are referenced to the top of the rack.