2.5.9.4 
Transmit Filter Specification 
Value 
Parameter 
1
Condition 
Min 
Max 
Unit 
Pass Band 
 
851.0125  
869.9875 
MHz 
Pass Band Insertion 
Loss 
Referenced to a 50 ohm 
impedance 
 2.0 
dB 
Pass Band Ripple 
Referenced to a 50 ohm 
impedance 
-0.5 +0.5 dB 
Stop Band 
Attenuation  
Referenced to a 50 ohm 
impedance 
-60  
dBc 
Note 1: Unless otherwise stated, all values are referenced to the top of the rack. 
 
Refer to Appendix E for filter curve. 
2.5.9.5 
Receive Filter Specifications 
Value 
Parameter 
1
Condition 
Min 
Max 
Unit 
Pass Band 
 
806.0125  
824.9875 
MHz 
Pass Band Insertion 
Loss 
Referenced to a 50 ohm 
impedance 
 1.0 
dB 
Pass Band Ripple 
Referenced to a 50 ohm 
impedance 
-0.5 +0.5 dB 
Stop Band 
Attenuation  
Referenced to a 50 ohm 
impedance 
-60  
dBc 
Note 1: Unless otherwise stated, all values are referenced to the top of the rack. 
 