RadioFrame Networks Inc MCSERIES10 User Manual

Page of 152
MC-Series System Installation & Testing 
Pre-Installation 
34 
RadioFrame Networks, Inc.
 
3.4 iDEN 
Configuration 
The MC-Series System supports WiDEN (Quad BRs) and the use of four adjacent channels and 
remote control of these settings. Plan to set up the MC-Series System according to the base 
radio (BR) parameters specified in the site datafill for the site, including cabinet, position, and 
Quad. Corresponding parameters will be set using the System Manager iDEN Configuration page 
during system set up (section 5.5). For more information about site datafill parameter settings, 
refer to the iDEN OMC-R Configuration Management Parameters Technical Manual
68P80802E10.  
3.4.1 
Cabinet and Position Settings 
Each RadioBlade in the MC-Series System operates as a BR. The system ships with default 
cabinet and position settings that must be changed during system set up to match the site datafill 
BR settings. The iSC then sets up each RadioBlade (BR) with a specific carrier.  
3.4.2 Quad 
BRs 
Within the RadioBlade Shelf (RBS), RadioBlades are arranged in three groups of up to 8 
RadioBlades. A maximum of one quad BR can be configured in each group. To do this, 
determine the cabinet/position settings, if any, to be assigned the quad BR from the parameters 
in the datafill. If a quad BR is selected, four RadioBlades from that group will be assigned to a 
single BR, leaving the remaining four RadioBlades to be used as EBRCs. When configuring a 
quad BR in the datafill (for use in the MC-Series), the number of carriers must be equal to four. 
The MC-Series System also supports EBRCs configured with adjacent channels. Instead of 
configuring a quad BR in the datafill, configure four EBRCs using four adjacent channels (each 
adjacent BR is assigned a separate cabinet/position). 
3.4.3 Sectorization 
In an omni (single-sector) configuration, all BRs are assigned to the same sector. In a 2- or 3-
sector configuration, each group (A, B, and C) may be assigned to a different sector. In this case, 
all RadioBlades within the group must be assigned to the same sector—multiple sectors cannot 
be assigned within the same group.