MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
62 
RadioFrame Networks, Inc.
 
LED 
Indication 
Condition 
Corrective action 
 
not lit 
no power to AIC 
 Verify that AIC circuit breaker on PDU is 
ON. 
 Check power connection to PDU. 
 Measure power input, and compare with 
tolerances listed in section 2 
“Specifications”. 
 Verify that the power source is 
operational. 
 Contact the TAC:  (800) 328-0847 
green normal 
condition 
none 
not lit 
card(s) not receiving power 
 Verify power to AIC (see “POWER” 
above) 
STATUS 
red 
PLLs are not locked 
 Verify that the STATUS LED on the BIC 
CRIC is green 
 Check the Alarm Manager for PLL LOCK 
alarm; wait 3 minutes for PLLs to lock; if 
they do not: 
 Verify integrity of Ethernet connection 
between BIC and AIC. 
 Contact the TAC:  (800) 328-0847 
 
7.3.3 RBS 
LED 
Indication 
Condition 
Corrective action 
green normal 
condition 
none 
STATUS 
not lit 
no power to RBS 
 Verify that RBS circuit breaker on 
PDU is ON. 
 Check power connection to PDU. 
 Measure power input, and compare 
with tolerances listed in section 2 
“Specifications”. 
 Verify that the power source is 
operational. 
 Contact the TAC:  (800) 328-0847