MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
86 
RadioFrame Networks, Inc.
 
7.4.5.7 COMMANDED 
RESET 
Cause: 
A commanded reset was issued from the system manager 
Flags: 
Further Action: 
N/A 
7.4.5.8 
LAPD LINK FAIL 
Cause: 
The lapd link was lost to the ISC. 
Flags: 
Further Action: 
The event will be removed in the future since a SET/CLEAR alarm is 
now present in the alarm manager. 
7.4.5.9 RB 
ALARMS-MISC 
Cause: 
One or more RadioBlades generated an alarm. 
Flags: 
Further Action: 
Operator should check the alarm status of all RadioBlades to see if any 
are generating too many alarms.  This event will be removed with the 
next version of SW and be replaced by a more robust RadioBlade alarm 
reporting method. 
7.4.5.10 RB 
LOCK 
Cause: 
An iDEN RadioBlade was locked from the system manager. 
Flags: 
Further Action: 
N/A 
7.4.5.11 
RB TX GAIN CAL 
Cause: 
System could not set proper Tx gain level on RadioBlade. Set default 
level instead. 
Flags: 
Further Action: 
User should identify the blade and check for proper Tx Power Level. If 
the blade is too far out of spec, then reseat the RadioBlade or Replace 
the RadioBlade. 
7.4.5.12 RB 
UNLOCK 
Cause: 
An IDEN RadioBlade was unlocked from the system. 
Flags: 
Further Action: 
N/A