MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
86
RadioFrame Networks, Inc.
7.4.5.7 COMMANDED
RESET
Cause:
A commanded reset was issued from the system manager
Flags:
Further Action:
N/A
7.4.5.8
LAPD LINK FAIL
Cause:
The lapd link was lost to the ISC.
Flags:
Further Action:
The event will be removed in the future since a SET/CLEAR alarm is
now present in the alarm manager.
now present in the alarm manager.
7.4.5.9 RB
ALARMS-MISC
Cause:
One or more RadioBlades generated an alarm.
Flags:
Further Action:
Operator should check the alarm status of all RadioBlades to see if any
are generating too many alarms. This event will be removed with the
next version of SW and be replaced by a more robust RadioBlade alarm
reporting method.
are generating too many alarms. This event will be removed with the
next version of SW and be replaced by a more robust RadioBlade alarm
reporting method.
7.4.5.10 RB
LOCK
Cause:
An iDEN RadioBlade was locked from the system manager.
Flags:
Further Action:
N/A
7.4.5.11
RB TX GAIN CAL
Cause:
System could not set proper Tx gain level on RadioBlade. Set default
level instead.
level instead.
Flags:
Further Action:
User should identify the blade and check for proper Tx Power Level. If
the blade is too far out of spec, then reseat the RadioBlade or Replace
the RadioBlade.
the blade is too far out of spec, then reseat the RadioBlade or Replace
the RadioBlade.
7.4.5.12 RB
UNLOCK
Cause:
An IDEN RadioBlade was unlocked from the system.
Flags:
Further Action:
N/A