MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
RadioFrame Networks, Inc.
  
89 
7.5.3 Alarm 
Descriptions 
Within the RF shelf there are a number of failure mechanisms that will generate an alarm. 
However, since only two alarm inputs are available in each RBS group, the alarms within the RF 
shelf must be AND'd together. The following table shows what constitutes a major alarm and 
what constitutes a minor alarm. 
 
Minor Alarm 
Major Alarm 
SINGLE FAN FAILURE 
LNA (RECEIVE PATH) ALARM 
 
LNA (DIVERSITY PATH) ALARM 
 PA 
ALARM 
 TWO 
FAN 
FAILURE 
 
TWO LNA POWER SUPPLY FAILURE 
 
TWO PA POWER SUPPLY FAILURE 
 
ONE PA POWER SUPPLY FAILURE 
 
ONE LNA POWER SUPPLY FAILURE 
7.6  Serial Log Upload Procedure 
Complete this procedure before disconnecting and removing the BIC, AIC, RBS or an RF shelf 
from the MC-Series System rack, or at the direction of RadioFrame Networks technical support. 
Select the Diagnostics tab in System Manager, and then select the Serial Log Upload link.