RadioFrame Networks Inc MCSERIESHP10 User Manual
MC-Series High-Power System
System Configuration Changes
998--01 Rev X1
RadioFrame Networks, Inc.
CONFIDENTIAL AND PROPRIETARY 103
Figure 73 Download and Reset Links
Note: iDEN Cabinet/Sector Information is not preserved in a downgrade from a 14.0
MCRB release to any non-MCRB release. Care should be taken to record this
information and re-enter it as necessary after a downgrade.
information and re-enter it as necessary after a downgrade.
Note: In the following procedures, ffs0 is partition A; ffs1 is partition B.
3 Using the inactive partition—“Download Version A” or “Download Version B” in
System Manager—navigate to the /platform/loads/MC-Series directory, and then
run the download on the following two files (observe the Download Successful
page; if a file fails, download it again):
run the download on the following two files (observe the Download Successful
page; if a file fails, download it again):
rom_staging.txt
plat_staging.txt
The inactive partition is the one that is not selected under System Reset (A or B). Browse
for the file in the text box of the inactive partition, A or B, and then select the Download to
Version… button.
for the file in the text box of the inactive partition, A or B, and then select the Download to
Version… button.