RadioFrame Networks Inc MCSERIESHP10 User Manual

Page of 131
Scheduled and Unscheduled Maintenance 
 
MC-Series High-Power System 
  
998--01 
Rev 
X1 
80 
CONFIDENTIAL AND PROPRIETARY 
RadioFrame Networks, Inc. 
 
TRADE SECRET INFORMATION 
Table 26  Alarm Details Fields 
Alarm Details Field 
Description 
Alarm Type 
Communication : failure to convey information 
Quality of service : signal degradation 
Processing error: software processing fault 
Equipment: equipment fault 
Environmental: condition with the equipment enclosure 
Eqpt Chassis 
Affected chassis:  bic or aic 
Eqpt Rfu/Rbs 
Affected RBS group:  grp A, grp B, or grp C 
Eqpt Slot 
Affected chassis slot: BIC (1-5), AIC (1-5), or RBS (1-24) 
Eqpt Type 
rfn:  unknown 
rlic:  BIC CRIC 
bpc:  BPC or BPC+SPAM 
ric:  AIC CRIC 
rbs:  RBS 
idenrb:  RadioBlade transceiver 
Eqpt Mac 
MAC address of the affected component 
System Reaction 
The action taken by the system as a result of the alarm 
Further Repair Actions 
Corrective action that should be taken as a result of the alarm 
State Change 
Not currently used (displays ‘false’ by default) 
Additional Info 
Miscellaneous 32-bit field 
7.5.2  OMC Alarm Code 
All RFS MC-Series alarms sent to the OMC use the Sprint Nextel Alarm Code 35009. 
Table 27 shows the properties for this alarm code. The Event Description
 for this alarm is 
'Unable to key BR'.  
Table 27  Alarm Code 35009 Properties 
Event 
Description 
Sprint Nextel Alarm Code 
35009 
Event Type 
CntrlBrd 
Alarm Type 
Equipment Failure 
Actionable Yes 
Severity 
Minor, Major or Critical 
Bounce Threshold (x) 
Bounce Threshold Minutes 
30 
Duration Threshold 
10 
Related Alarms 
None 
R & C 
RC 
Outage Y/N 
S1_El CY 
Event Description 
Unable to key BR