RadioFrame Networks Inc MCSERIESHP10 User Manual
Scheduled and Unscheduled Maintenance
MC-Series High-Power System
998--01
Rev
X1
80
CONFIDENTIAL AND PROPRIETARY
RadioFrame Networks, Inc.
TRADE SECRET INFORMATION
Table 26 Alarm Details Fields
Alarm Details Field
Description
Alarm Type
Communication : failure to convey information
Quality of service : signal degradation
Processing error: software processing fault
Equipment: equipment fault
Environmental: condition with the equipment enclosure
Quality of service : signal degradation
Processing error: software processing fault
Equipment: equipment fault
Environmental: condition with the equipment enclosure
Eqpt Chassis
Affected chassis: bic or aic
Eqpt Rfu/Rbs
Affected RBS group: grp A, grp B, or grp C
Eqpt Slot
Affected chassis slot: BIC (1-5), AIC (1-5), or RBS (1-24)
Eqpt Type
rfn: unknown
rlic: BIC CRIC
bpc: BPC or BPC+SPAM
ric: AIC CRIC
rbs: RBS
idenrb: RadioBlade transceiver
rlic: BIC CRIC
bpc: BPC or BPC+SPAM
ric: AIC CRIC
rbs: RBS
idenrb: RadioBlade transceiver
Eqpt Mac
MAC address of the affected component
System Reaction
The action taken by the system as a result of the alarm
Further Repair Actions
Corrective action that should be taken as a result of the alarm
State Change
Not currently used (displays ‘false’ by default)
Additional Info
Miscellaneous 32-bit field
7.5.2 OMC Alarm Code
All RFS MC-Series alarms sent to the OMC use the Sprint Nextel Alarm Code 35009.
Table 27 shows the properties for this alarm code. The Event Description
Table 27 shows the properties for this alarm code. The Event Description
for this alarm is
'Unable to key BR'.
Table 27 Alarm Code 35009 Properties
Event
Description
Sprint Nextel Alarm Code
35009
Event Type
CntrlBrd
Alarm Type
Equipment Failure
Actionable Yes
Severity
Minor, Major or Critical
Bounce Threshold (x)
3
Bounce Threshold Minutes
30
Duration Threshold
10
Related Alarms
None
R & C
RC
Outage Y/N
S1_El CY
Event Description
Unable to key BR