Scheduled and Unscheduled Maintenance 
998--01 Rev X1 
RadioFrame Networks, Inc. 
CONFIDENTIAL AND PROPRIETARY 87 
 
 
•  Primary iSC-3; then ensure that the power switch on the front of the unit is in the 
OFF position 
7.9  Field Replaceable Unit (FRU) Procedures 
The MC-Series system has been designed so that Field Repairable Units (FRUs) can be 
replaced to restore normal system operation as quickly as possible.  
Refer to section 1.3 “Repair and Technical Support”, Table 1, which lists RadioFrame 
Networks FRUs. Do not attempt to repair RadioFrame Networks equipment and 
components in the field. Be sure to read section 1.3.2 “Field Replaceable Unit (FRU) 
Policy”. 
For support of RadioFrame Networks equipment, contact the RadioFrame Networks 
Technical Assistance Center (TAC) at:  
(US)  1-800-328-0847 
For equipment not supplied by RadioFrame Networks, follow standard Sprint Nextel 
policies and procedures for FRU replacement.  
7.9.1  RF Shelf 
<<<<TO BE SUPPLIED>>>> 
Figure 54  RF Shelf Front View 
 
Figure 55  RF Shelf Rear View 
 
7.9.2  Replacing an ABIC Chassis 
<<<<TO BE SUPPLIED>>>> 
7.9.3  ABIC  FRU Replacement Procedure 
BEFORE REPLACING ANY CARD (board) in the BIC or AIC, power down RadioFrame 
Networks equipment in the following order using circuit breakers on the PDU: 
• BIC 
• AIC 
•  RBS 1 (power down RBS 2 if present) 
•  RF Shelves 1, 2 and 3 
7.9.3.1 Replacing 
the 
CRIC 
1  Before replacing any card (board) power down RadioFrame Networks equipment in 
the following order using circuit breakers on the PDU: 
ƒ
  ABIC 
ƒ
  RBS 1 (and power down RBS 2 if present) 
ƒ
  RF Shelves 1, 2 and 3