RadioFrame Networks Inc MCSERIESHP10 User Manual
Scheduled and Unscheduled Maintenance
MC-Series High-Power System
998--01
Rev
X1
94
CONFIDENTIAL AND PROPRIETARY
RadioFrame Networks, Inc.
TRADE SECRET INFORMATION
Figure 61 Seating the RadioBlade Transceiver
7 Connect the Rx and Tx cables to the correct ports on the RadioBlade transceiver,
and use the SMA torque wrench to tighten.
8 Re-insert the RBS into its chassis. To do this, press up on one side rail locking arm
and press down on the other side-rail locking arm, and then push the unit into the
rack (see Figure 62).
rack (see Figure 62).
Figure 62 RF Shelf Showing Side-Rail Locking Arm Locations
locking arm
locking arm
9 In System Manager, refresh the RBS Status page until the RadioBlade transceiver
icon status bar changes from red (not present) to yellow (present and locked). This
will take approximately three minutes.
will take approximately three minutes.
10 Unlock the RadioBlade transceiver.
On the RadioBlade Transceiver Control page, the State of the RadioBlade transceiver will
change from 2 (locked) to 11 (unlocked).
change from 2 (locked) to 11 (unlocked).
7.9.5 Power Distribution Unit
The Power Distribution Unit (PDU) receives DC input and supplies power via dedicated
circuit breakers to each component in the MC-Series system. Each of the thirteen
circuit breakers to each component in the MC-Series system. Each of the thirteen