RadioFrame Networks Inc MCSERIESHP10 User Manual

Page of 131
Scheduled and Unscheduled Maintenance 
 
MC-Series High-Power System 
  
998--01 
Rev 
X1 
94 
CONFIDENTIAL AND PROPRIETARY 
RadioFrame Networks, Inc. 
 
TRADE SECRET INFORMATION 
Figure 61  Seating the RadioBlade Transceiver 
 
7  Connect the Rx and Tx cables to the correct ports on the RadioBlade transceiver, 
and use the SMA torque wrench to tighten. 
8  Re-insert the RBS into its chassis. To do this, press up on one side rail locking arm 
and press down on the other side-rail locking arm, and then push the unit into the 
rack (see Figure 62). 
Figure 62  RF Shelf Showing Side-Rail Locking Arm Locations 
 
locking arm 
locking arm
 
9  In System Manager, refresh the RBS Status page until the RadioBlade transceiver 
icon status bar changes from red (not present) to yellow (present and locked). This 
will take approximately three minutes. 
10 Unlock the RadioBlade transceiver. 
On the RadioBlade Transceiver Control page, the State of the RadioBlade transceiver will 
change from 2 (locked) to 11 (unlocked). 
7.9.5  Power Distribution Unit 
The Power Distribution Unit (PDU) receives DC input and supplies power via dedicated 
circuit breakers to each component in the MC-Series system. Each of the thirteen