RadioFrame Networks Inc MCSERIESMP User Manual

Page of 167
MC-Series System Installation & Testing 
Scheduled and Unscheduled Maintenance 
100 
RadioFrame Networks, Inc.
 
Mount the replacement chassis.  
While supporting the chassis, slide the chassis into the cabinet mounting position. Secure the 
chassis to the cabinet mounting rails using the four mounting screws provided with the unit. 
Tighten the screws to 4.5 Nm (40 in-lb).  
Reconnect the cabling to the replacement chassis as defined in Step 2.  
Use the SMA torque wrench for all SMA connectors. 
Using the breakers on the PDU, turn up the BICAIC, and RBS 1 (and RBS 2 and RBS 3 if 
present), and then verify that the components are operational before proceeding. 
Wait approximately 3 minutes for the following indicators: 
• 
RBS:  The STATUS LED for each group will light green in this order: A, B, and then C.  
• 
RBS:  The RADIOBLADE STATUS LEDs will light red and then green for each present 
RadioBlade. If no RB is present, the LED will not light. To verify the contents of the RBS, 
pull out the shelf (powering off is not required) and inspect the RadioBlades and their 
respective status LEDs. Reinsert the RBS. To do this, press up on one side rail locking 
arm and press down on the other side rail locking arm, and then push the unit into the 
rack (see the following illustration). 
• 
BIC CRIC and AIC CRIC:  The POWER and STATUS LEDs will light red and then green. 
All other BIC and AIC card LEDs will light green. 
Using the breaker on the PDU, turn up each RF Shelf and then verify that each RF Shelf is 
operational before proceeding. The POWER and ALARM LEDs on the front of the RF Shelf 
will light green. 
Complete the procedures in sections 5.4, 5.5 and 5.6. 
7.9.2.3 
RBS 1 (power down RBS 2 and RBS 3 if they are present) 
Power down RFN equipment in the following order using circuit breakers on the PDU: 
• 
BIC 
• 
AIC 
• 
RBS 1 (power down RBS 2 and RBS 3 if they are present) 
• 
RF Shelves 1,2 and 3 
Disconnect cabling from the back of the RBS to be replaced. 
For RBS 1, disconnect the following cabling from the rear of the RBS 1 only: 
NOTE:  If RBS 2 and RBS 3 are present, refer to Appendix C Cabling Diagrams: 3-Sector 
Configuration and Appendix D Cabling Diagrams: Omni Configuration. 
 
Index 
Part Number 
Disconnect From 
To 
Type 
P_6 
820-0616-50 
RBS 1:  power 
PDU:  RBS 1 
power 
G_8 
820-0609-00 
RBS 1:  ground 
GND BAR 
ground 
RF_1 
820-0611-20 
RBS 1:  Tx A 
RF Shelf 1:  Tx IN A  
RF cable