RadioFrame Networks Inc MCSERIESMP User Manual

Page of 167
MC-Series System Installation & Testing 
System Configuration Changes 
RadioFrame Networks, Inc.
  
121 
Reconnect terminations to: 
• 
RF Shelf 2: Tx IN B and Rx OUT B 
• 
RF Shelf 3: Tx IN C and Rx OUT C 
The disconnected RF shelf (or shelves) remain in the rack and must remain unpowered.  
The following cables may remain as long the RF shelf remains unpowered: 
Index 
Part Number 
From 
To 
Type 
AL_2 
820-0607-00 
RF Shelf 2:  ALARM 
RBS:  ALARM INPUT B 
serial 
RF_15 
820-0610-30 
RF Shelf 2:  TX OUT 
TOR:  Tx 2 
RF cable 
RF_16 
820-0610-30 
RF Shelf 2:  RX IN 
TOR:  Rx 2 
RF cable 
AL_3 
820-0607-00 
RF Shelf 3:  ALARM 
RBS:  ALARM INPUT C 
serial 
RF_21 
820-0610-30 
RF Shelf 3:  TX OUT 
TOR:  Tx 3 
RF cable
 
RF_22 
820-0610-30 
RF Shelf 3:  RX IN 
TOR:  Rx 3 
RF cable
 
 
Place dust caps (RFN P/N: 546-0005-00) on cables (end not going to TOR): 
• 
RF Shelf 2:  RF_15 and RF_16 
• 
RF Shelf 3:  RF_21 and RF_22 
10 
Place dust caps (RFN P/N: 546-0003-00) on the TOR: 
• 
RF Shelf 2:  Tx 2 and Rx 2 
• 
RF Shelf 3:  Tx 3 and Rx 3 
11 
Push the new datafill load to the iSC. 
12 
Using the breakers on the PDU, turn up the BICAIC, and RBS 1 (RBS 2 and RBS 3 if 
present), and then verify that the components are operational before proceeding. 
• 
RBS:  The STATUS LED for each group will light green in this order: A, B, and then C.  
• 
RBS:  The RADIOBLADE STATUS LEDs will light red and then green for each present 
RadioBlade. If no RB is present, the LED will not light. To verify the contents of the RBS, 
pull out the shelf (powering off is not required) and inspect the RadioBlades and their 
respective status LEDs. Reinsert the RBS. To do this, press up on one side rail locking 
arm and press down on the other side rail locking arm, and then push the unit into the 
rack (see the following illustration). 
• 
BIC CRIC and AIC CRIC:  The POWER and STATUS LEDs will light red and then green. 
All other BIC and AIC card LEDs will light green. 
13 
Using the breakers on the PDU, turn up RF Shelf 1 only. Do not turn up RF Shelf 2 and RF 
Shelf 3 unless part of the new configuration. Verify that RF Shelf 1 is operational before 
proceeding. 
The POWER and ALARM LEDs on the front of each RF Shelf will light green.