2.5.8 Heat 
Load 
Supplier 
Component 
BTUs per Hour 
RadioFrame Networks 
BIC 
340 
 AIC 
340 
 RBS 
320 
 RF 
Shelf 
680 
 PDU 0 
Non-RFN iSC-3 
140 
 EAS 
170 
 CSU 
17 
 
2.5.9 RF 
Performance 
The MC-Series System will meet the emissions mask requirements per FCC Part 90, section 
90.691. 
2.5.9.1 
Frequency of Operation  
Band 
Receive Frequency (MHz) 
Transmit Frequency (MHz) 
800E 
806.0125 to 824.9875 
851.0125 to 869.9875 
2.5.9.2 
Transmitter Performance Summary  
Value 
Parameter 
1
Condition 
Min 
Typ 
Max 
Unit 
2
Tx Output Power per 
carrier (maximum) 
Typical output power  
+8.0 
+10 
+12 
dBm 
Tx Power Output 
Range per carrier 
 -20 
 
+10 
dBm 
Tx Output Power 
Variation 
-20dBm 
≤ Pout ≤ +10 dBm 
851.0125 
≤ f ≤ 869.9875 MHz
 
-2.0  2.0 dB 
Transmit port VSWR 
Referenced to a 50 ohm 
impedance 
  
2:1 
Downlink Signal Quality 
Estimator (SQE) 
Average value 
30 
 
 
dB 
Occupied bandwidth  
Per carrier 
 
18.5 
 
kHz 
RF Frequency 
Tolerance (TX) 
Average frequency 
 
 
± 50 
Hz 
Note 1: Unless otherwise stated, all values are referenced to the top of the rack.