MC-Series System Installation & Testing 
Installation 
RadioFrame Networks, Inc.
  
41 
4.4.1 iSC-3s 
While supporting the iSC-3, slide the iSC-3 into the cabinet mounting position. 
Mount the iSC-3 in the location shown in the cabinet illustration earlier in this section. If 
necessary, install side rails in the mounting position in the rack. 
Secure the iSC-3 to the cabinet mounting rails using the four mounting screws provided with 
the unit. Tighten the screws to 4.5 Nm (40 in-lb). 
Connect the RFN-provided ground cable (P/N 820-0609-10; ISC1 to GND BAR) between the 
cabinet ground bar and the grounding lug on the rear of the iSC-3, and ensure the connection 
is tight.  
Connect the RFN-provided power cable (P/N 820-0613-50; PDU-CTRL_1 to ISC1) between 
the iSC-3 power and the CTRL circuit breaker on the PDU (CTRL 1 for the primary iSC and 
CTRL 2 for the secondary iSC).  
Repeat steps 1 through 4 to mount the secondary iSC-3 (cable labels will show ISC2 instead 
of ISC1). 
Connect the two iSC-3s according to Nextel’s installation procedure. 
Using the RFN-provided coax cable (P/N 111-0001-02; BIC-ERTM 5MHz IN to ISC1 REF 
OUT-1), connect the primary iSC-3 port SITE REF OUT 1 to the BIC ERTM port 5MHz IN.  
Terminate the two remaining SITE REF OUT ports on the primary iSC-3, and terminate all 
three SITE REF OUT ports on the secondary iSC-3. 
Using the RFN-provided coax cable (P/N 111-0001-02; BIC-CRTC to ISC1 REF OUT-1), 
connect the primary iSC-3 port 10B2-1 to the BIC CRTC port 10Base2 ISC
10 
Terminate the two remaining iSC-3 10B2 ports on the primary iSC-3, and terminate all three 
10B2 ports on the secondary iSC-3. 
For complete cabling information, refer to Appendix C Cabling Diagrams: 3-Sector 
Configuration. 
 