Template update: 00-12-01 
 
 
1.  The TI and NI are monitored continuously. 
2.  When both the TI and NI become inactive the intercom session with the first receiver paired 
with the base unit is terminated. 
3.  If the previous state was the Idle state or the MF is inactive the base unit is moved to Idle 
state. 
4.  If the previous state was the AV State and the MF is active an AV connection is initiated. If 
successful, the unit is moved to the AV State. If unsuccessful an LED-Fail is issued and the 
unit is moved to the Idle state. 
The intercom session with the first receiver paired with the base unit can be terminated from the 
receiver if it receives a phone call. Then the termination request is accepted and the base unit is 
moved to the Idle state. If the TI is still active a retry to establish an intercom session with the first 
receiver paired with the base unit is performed every 5 seconds. 
3.3.9  Prioritized Audio Messages functionality 
The prioritized audio messages (e.g. navigation information from GPS) functionality does not have an 
own state. It uses the active session to transmit the info to the receiver(s). The NI becomes active 
before the navigation info is sent and goes inactive when the info is finished. 
1.  If an AV session is active the navigation info is sent to the receivers using that. 
2.  If an intercom session with the first receiver paired with the base unit session is active the 
navigation info is sent using that. 
In both cases the Bluetooth unit does not actively use the NI. 
If the base unit is in the Idle state and the NI becomes active an intercom session with the first 
receiver paired with the base unit is established and the navigation info is sent using that. The 
intercom session with the first receiver paired with the base unit is terminated according to 3.3.8.2.