Comba Telecom Ltd. COMFLEX-6900 User Manual

Page of 66
USER MANUAL FOR COMFLEX-6900  
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 19 
 
  Always  maintain  the  minimum  bending  radius  specified  by  the  cable  manufacturer.  The  minimum 
bend radius is usually 10 times the cable’s outer diameter. In the case of single optical fiber that is 
not in a cable, the minimum bending radius to be observed is 3cm. (1.2”) . 
 
 
3.3.4 MU ASSEMBLING  
ComFlex  Master  Unit  consists  of  4  parts:  Chassis,  RFU,  FOU  and  PSU.  All  the  units  are  packed 
separately. Follow the steps below to assemble. 
 
Figure 5: ComFlex Master Unit 
 
Step1: RF Unit installation: Remove RFU slot cover plate on Chassis, insert RFU and fasten the screws. 
(Each Unit can be installed in any one of eight RFU slots) 
 
 
Figure 6: RF Unit Installation 
 
Step2:
  FOU  installation:  Remove  FOU  slot  cover  plate  on  Chassis,  insert  FOU  and  fasten  the  screws. 
(Each Unit can be installed in either one of two FOU slots)