Always maintain the minimum bending radius specified by the cable manufacturer. The minimum
bend radius is usually 10 times the cable’s outer diameter. In the case of single optical fiber that is
not in a cable, the minimum bending radius to be observed is 3cm. (1.2”) .
3.3.4 MU ASSEMBLING
ComFlex Master Unit consists of 4 parts: Chassis, RFU, FOU and PSU. All the units are packed
separately. Follow the steps below to assemble.
separately. Follow the steps below to assemble.
Figure 5: ComFlex Master Unit
Step1: RF Unit installation: Remove RFU slot cover plate on Chassis, insert RFU and fasten the screws.
(Each Unit can be installed in any one of eight RFU slots)
(Each Unit can be installed in any one of eight RFU slots)
Figure 6: RF Unit Installation
Step2: FOU installation: Remove FOU slot cover plate on Chassis, insert FOU and fasten the screws.
(Each Unit can be installed in either one of two FOU slots)