FTLX8511D3 Datacom XFP Product Specification – May 2007   
F i n i s a r
 
 
 
© Finisar Corporation  31-May-2007 
Rev C 
Page 4 
 
III. Electrical 
Characteristics 
(T
OP
 = 0 to 70 
°C, V
CC3
 = 3.13 to 3.45 Volts) 
 
 
Parameter Symbol 
Min 
Typ 
Max 
Unit 
Ref. 
Supply Voltage 
Vcc3 
3.13 
 
3.45 
 
Supply Current 
Icc3 
 
 
400 
mA 
 
Module total power 
 
 
1.5 
Transmitter 
 
 
 
 
 
 
Input differential impedance 
R
in
 100   
Ω 
Differential data input swing  
Vin,pp
 
120  1000 
mV 
 
Transmit Disable Voltage 
V
D
2.0  Vcc V 
Transmit Enable Voltage 
V
EN
GND  
 
GND+ 0.8 
 
Transmit Disable Assert Time 
 
  10 
us 
 
Receiver 
 
 
 
 
 
 
Differential data output swing  
Vout,pp
 
600 650  800 mV 
Data output rise time 
t
r
  40 
ps 
Data output fall time 
t
f
  40 
ps 
LOS Fault  
V
LOS fault
Vcc – 0.5 
 
Vcc
HOST
V 6 
LOS Normal 
V
LOS norm
 
 
GND  
 
GND+0.5 
Power Supply Rejection 
PSR
 
See Note 6 below 
 
Notes: 
1.  Maximum total power value is specified across the full temperature and voltage range. 
2.  After internal AC coupling. 
3.  Or open circuit. 
4.  Into 100 ohms differential termination. 
5.  20 – 80 %. 
6.  Loss Of Signal is open collector to be pulled up with a 4.7k
Ω – 10kΩ resistor to 3.15 – 3.6V. Logic 0 
indicates normal operation; logic 1 indicates no signal detected. 
7.  Per Section 2.7.1. in the XFP MSA Specification
1
.