Capital Circuit Works Inc. XP100 User Manual
Installation/Test procedure for Live Trap System:
1. Place Live trap in the area required and mount Transmitter on Cage door frame
as shown in Fig 3.
2. Install Receiver unit in a room as close as possible to the Live Trap cage and
transmitter (maximum of 40 feet)
3. Connect Power adapter module to power connector on side of Receiver unit (there
should be no buzzing or LED flashing)
4. Activate Live trap cage door and ensure the red LED on the transmitter lights for
Aprox 1 sec.
5. Lift door on Live trap cage .
6. Go down to room where Receiver is and verify that Receiver has been activated.
6. Go down to room where Receiver is and verify that Receiver has been activated.
RED LED and Buzzing sound)
7. Unplug power from Receiver unit to reset system.
Proper storage of the Live Trap Transmitter:
The transmitter will start transmitting when the side labeled this side down is facing
downward. To maximize transmitter battery life always store the transmitter with such
that the side that states this side down - is facing up. (This ensures that the transmitter
is disabled) Proper storage will ensure up to 1 year Transmitter battery life.