Master Key I und Master Key II
Master Key I
Master Key I is only used by the system operator to unlock the LSW. It is intended for personnel with
restricted locking permissions. Master Key I can only be used for unlocking the LSW if it was locked
with a User Key.
After being unlocked with Master Key I, the LSW is blocked from use of a User Key or User
Code.
This block first needs to be reset with Master Key II.
Master Key II
Master Key II can be used at any time to unlock or lock the LSW or to release an LSW that has been
blocked using Master Key I.
Programming prior to use of Master Keys
The Master Keys can be programmed in conjunction with Lock Manager 6 software prior to use. The
following parameters can be set for the Master Keys:
Lock number or lock number range
Valid from, valid to
These configuration options allow enabling of the Master Keys for a specific lock or lock range only
as well as for a certain period.
The last ten uses of the Master Key at the LSW are stored on the Master Key. This information can
be read using Lock Manager 6 software. In this way, use of the Master Key can also be indicated
without having to read a lock log.
Note: Programming of the Master Keys is only possible in conjunction with Lock Man-
ager 6 software.
Note: Each time the Master Key is used, this is also recorded in the lock log of the
LSW.
Please refer to the Lock Manager 6 guide for more information on programming Mas-
ter Keys.