Schulte-Schlagbaum AG LSW User Manual

Page of 29
Guide 
SAFE-O-TRONIC
®
 access
 
LSW 
 
Schulte-Schlagbaum AG 
Page 17 of 28 
 LSW_6-703-2 33S1 3.docx
  
                                                                                                                                        
 
Information  
 
LED display 
All important actions and operating modes are indicated by the LED display, the 
aim being to provide assistance in finding faults and operating errors. An expla-
nation of the individual signals is provided in the table below. 
 
Status messages 
Green 
Red 
Green 
Red 
Display 
Action 
 
 
 
 
Rapid flashing 
Programming mode 
 
 
 
 
Every 3 seconds 
Blocking time (one minute) is 
active. An incorrect code was 
entered four times 
 
 
 
 
1 second 
Key input  
 
 
 
 
1 second 
Abort key (“X”) was pressed 
 
 
 
 
LEDs flash alterna-
tively three times 
Handling error, the bolt could 
not be activated within the 
release time 
 
 
 
 
1 second 
LSW was locked / program-
ming successful 
 
 
 
 
2 seconds 
LSW was unlocked 
 
 
 
 
½ second  
Code was accepted 
 
 
 
 
3 seconds 
Internal function fault / LSW 
must be replaced where 
necessary 
 
 
 
 
Red LEDs flash first, 
followed by green 
LEDs (½ second in 
each case) 
Blocking activated by Master 
Code 1 / Master Key I was 
lifted by means of Master 
Code 2 / Master Key II 
 
 
 
 
LEDs all flash togeth-
er rapidly three times 
Code input rejected because 
blocking by Master Code 1 / 
Master Key I is active 
 
 
 
 
LEDs flash together 
three times 
Warning: Battery should be 
replaced soon 
 
 
 
 
LEDs flash alterna-
tively five times 
Battery must be replaced 
immediately, LSW can no 
longer be locked 
 
 
 
 
LEDs flash three 
times 
Reset performed 
 
 
 
 
LED flashes briefly. 
1x per second 
Status message: Cabinet 
locked