Radwin Ltd. RW2058 User Manual

Page of 211
Community String
Appendix F
RADWIN 1000/2000/5000 User ManualVersion  2.5.30p3
F-2
and ODUs in the link. Both agents communicate with each other over the air 
using a proprietary protocol.
To control and configure the device using the MIB, you should adhere to the 
following rules:
• The connection for control and configuration is to the local site, over 
any SNMP/UDP/IP network.
• All Parameters should be consistent between both of the ODUs. Note 
that inconsistency of air parameters can break the air connection. To 
correct air parameters inconsistency you must reconfigure each of 
the ODUs. 
• Common practice is to configure the remote site first and then to 
configure the local site.
• For some of the configuration parameters additional action must be 
taken before the new value is loaded. Please refer to the operation 
in the parameters description.
• Some of the MIB parameters values are product dependent. It is 
strongly recommend using the RADWIN Manager Application for 
changing these values. Setting wrong values may cause indetermi-
nate results.
Community String
To control a link, all SNMP requests should go to the local site IP address.
The RADWIN Manager uses the Read Community strings public for the 
local ODU and public-remote for the remote ODU. It uses Write Commu-
nity strings netman for the local ODU and netman-remote for the 
remote ODU. These are the factory defaults.
Private MIB Structure
The sections in the private RADWIN MIB and its location in the MIB tree are 
shown in 
Note
Each ODU has a single MAC address and a single IP address.