Radwin Ltd. RW2058U User Manual

Page of 211
Changing the Link Password
 Chapter 6
RADWIN 1000/2000/5000 User ManualVersion  2.5.30p3
6-14
 
Figure 6-11: Available security features
Changing the Link Password
This item is only available when the link is down. Otherwise, it works the 
same way as the corresponding item on 
RADWIN Manager Community Strings
The ODU communicates with the application using SNMPv1 protocol. The 
protocol defines three types of communities:
• Read-Only for retrieving information from the ODU
• Read-Write to configure and control the ODU
• Trap used by the ODU to issue traps.
The Community string must be entered at login. The user must know the 
password and the correct Community string to gain access to the system. A 
user may have read-only privileges.
It is not possible to manage the ODU if the read-write or the read Commu-
nity values are forgotten. A new Community value may be obtained from 
RADWIN Customer Support for the purpose of setting new Community; the 
serial number or the MAC address of the ODU must be supplied.
Note
The RADWIN Manager uses the Read Community strings public for the site 
Al ODU and public-remote for the site B ODU. It uses Write Community 
strings netman for the site A ODU and netman-remote for the site B 
ODU. These are the factory defaults.