AirMux-104 Installation and Operation Manual 
Chapter 4  Operation 
 
Managing AirMux-104 
4-5 
 
Figure 4-3.  Communication Preferences Dialog Box 
Selecting Configuration Parameters 
You can set the AirMux-104 configuration parameters via Configure Link dialog 
box.  
 
AirMux Manager also provides the Configure RT dialog box (Configure > Configure 
RT
), which is used to configure only the local AirMux-104 unit (the one that is 
connected to the management station). 
 
 
To change link configuration parameters: 
1.  In the Main menu, click Configure Link
The Configure Link dialog box appears (see 
2.  In the Configure Link dialog box, click the Radio tab and enter a new link 
name, and/or radio channel value, if necessary. 
3. Click the IP tab, and enter new IP parameters of the local and/or remote 
devices, if necessary. 
4. Click the Services tab, and change Ethernet and/or E1 parameters, if 
necessary. 
5.  Once you finish changing configuration parameters, click Apply
Both AirMux-104s are automatically reset (initially remote unit, then the 
local one).  